E48-06a Slow decrease and increase of the supply voltage – without energy storage –
緩やかな電圧降下及び上昇の試験パラメータ ー バッテリ無し ー
車載バッテリの緩やかな放電と充電における電源電圧の緩やかな低下と上昇をシミュレートしています。
E48-06a Slow decrease and increase of the supply voltage (without energy storage)
DUT Operating mode : Ⅱ.a and Ⅱ.c
- U0
- U48max,unlimited
- Stress gradient
- ±2 V/min
- U1
- U48min,unlimited
- U2
- 0 V
- t1
- Until the error memory has been read out completely
- Number of cycles
- 1 cycle with operating mode Ⅱ.a
1 cycle with operating mode Ⅱ.c
- Number of DUTs
- At least 6
Requirements: