E48-06c Slow decrease and increase of the supply voltage – with energy storage Part2-
緩やかな電圧降下及び上昇の試験パラメータ ー バッテリを含む part2 ー
バッテリなしで電気システムを動作させ、放電したバッテリを接続した場合の動作をシミュレートします。
E48-06c Slow decrease and increase of the supply voltage (with energy storage – Part 2)
DUT Operating mode : Ⅱ.b after reaching end voltage
| Ri |
≤ 60 mΩ |
| U0 |
0 V |
| U1 |
U48n |
| U48pp |
6 V at 10 kHz |
| U2 |
U48stoprotect |
| t0 |
100 ms |
| tr1 |
300 ms |
| t1 |
≥ 60 s (During this phase the fault memory is read out) |
| tf1 |
1 ms |
| tr2 |
14 min |
| t3 |
100 ms |
| Number of cycles |
1 |
| Number of DUTs |
6 |
Requirements: